Reconnecting an external display fails on initial page-flip. This occurs when the pageflip_pending flag has been set on the connector at the time the monitor is removed. Once the connector's CRTC has been deallocated, page_flip_handler cannot find the connector by its crtc_id, so pageflip_pending will remain set. This causes initialization to fail when the monitor is reconnected with the error messages: Skipping pageflip on output 'X' Failed to initialize renderer on connector 'X': initial page-flip failed To fix this problem, clear the pageflip_pending flag when cleaning up the connector. |
||
---|---|---|
.. | ||